CHD Interventions Featured Articles of January 2016

1. A new breakable stent for recoarctation in early infancy: Preliminary Clinical Experience.

Grohmann J, Sigler M, Siepe M, Stiller B.

Catheter Cardiovasc Interv. 2016 Jan 2. doi: 10.1002/ccd.26393. [Epub ahead of print]

PMID: 26724789

Similar articles

Select item 26774238

bouddjemlineMehul Patel photoComment from Pr. Younes Boudjemline (Paris) and co-editor Dr. Mehul Patel (Detroit, MI), editors of congenital heart disease interventions Journal Watch:  This is a retrospective study from a single center in Germany evaluating low-profiled, balloon-expandable, cobalt-chrome stent (Osypka BabyStent® ) to treat aortic re CoA or reobstruction of the aortic arch after former surgery in 4 infants. The stent is still investigational and comes precrimped on a valvuloplasty balloon catheter (Osypka VACS II 6.0/ 20 mm, nominal pressure 3.5 atm. (max. balloon diameter 6.6 mm at 4.0 atm. RBP), 0.018 inner lumen) ensuring 4 Fr sheath compatibility.  The unique hook and eye design is present in each cell aligned in a line. The elastic joints between the cells as well as hook and eye connections can be opened when the balloon diameter exceeds 12 mm. The median age of the study population was 10 weeks (range 5-21) with median gain in aortic diameter from median 2.25 mm to 5.3 mm. All procedures were technically successful and patients were followed for a median duration of 8.5 months.  The authors fairly concluded that BabyStent® implantation for recoarctation was effective. However since not enough somatic growth was achieved in this relatively short follow up period, none of  the stents required over dilatation, leaving that aspect of functionality unchecked. A prospective multicenter survey has been initiated by the group to derive more information.

Take home points:

  1. Once approved, this stent with radial force comparable to a coronary stent may be a very useful addition to the pediatric interventional armamentarium.
  2. More bench information may be required on the behavior of the fracture gap segment with respect to differential thickness, vulnerability to rupture and future dilatation.

interv 1.1

interv 1.2

interv 1.3

interv 1.4

interv 1.5

(No Ratings Yet)
Loading...Loading...

CHD Intervention Articles of January 2016

  1. Results of coil closure of patent ductus arteriosus using a tapered tip catheter for enhanced control.

Devanagondi R, Latson L, Bradley-Skelton S, Prieto L.

Catheter Cardiovasc Interv. 2016 Jan 23. doi: 10.1002/ccd.26415. [Epub ahead of print]

PMID: 26800854

Similar articles

Select item 26800085

 

  1. Perinatal outcomes and intrauterine complications following fetal intervention for congenital heart disease: systematic review and meta-analysis of observational studies.

Araujo Júnior E, Tonni G, Chung M, Ruano R, Martins WP.

Ultrasound Obstet Gynecol. 2016 Jan 22. doi: 10.1002/uog.15867. [Epub ahead of print]

PMID: 26799734

Similar articles

Select item 26799640

 

  1. Doubly committed subarterial ventricular septal defect: A risk factor for aortic distortion in patients considered for percutaneous pulmonary valve implantation?

Jivanji SG, Derrick G, Khambadkone S.

Catheter Cardiovasc Interv. 2016 Jan 17. doi: 10.1002/ccd.26412. [Epub ahead of print]

PMID: 26775289

Similar articles

Select item 26776918

 

  1. Comparison of surgical repair and percutaneous stent implantation for native coarctation of the aorta in patients ≥15years of age.

Yeaw X, Murdoch DJ, Wijesekera V, Sedgwick JF, Whight CM, Pohlner PG, Raffel OC, Walters DL.

Int J Cardiol. 2016 Jan 15;203:629-31. doi: 10.1016/j.ijcard.2015.11.052. Epub 2015 Nov 6. No abstract available.

PMID: 26580346

Similar articles

Select item 26562535

 

  1. A case of double fistulas of right coronary artery to LVOT and LAD.

Ozturk C, Arslan Z, Verim S, Unlu M, Demirkol S, Celik T, Iyisoy A.

Int J Cardiol. 2016 Jan 15;203:379-80. doi: 10.1016/j.ijcard.2015.10.104. Epub 2015 Oct 19. No abstract available.

PMID: 26539961

Similar articles

Select item 26519685

 

  1. Mathematics and transcatheter aortic valve implantation: Use of computational fluid dynamics and finite element analysis. Is this the future?

Zuin M, Rigatelli G, Roncon L.

Int J Cardiol. 2016 Jan 9;207:31-32. doi: 10.1016/j.ijcard.2016.01.138. [Epub ahead of print] No abstract available.

PMID: 26788818

Similar articles

Select item 26742958

 

  1. Exposure to Low-Dose Ionizing Radiation From Cardiac Procedures in Patients With Congenital Heart Disease: 15-Year Data From a Population-Based Longitudinal Cohort.

Beauséjour Ladouceur V, Lawler PR, Gurvitz M, Pilote L, Eisenberg MJ, Ionescu-Ittu R, Guo L, Marelli AJ.

Circulation. 2016 Jan 5;133(1):12-20. doi: 10.1161/CIRCULATIONAHA.115.019137. Epub 2015 Nov 4.

PMID: 26538581

Similar articles

Select item 26738930

 

  1. A new breakable stent for recoarctation in early infancy: Preliminary Clinical Experience.

Grohmann J, Sigler M, Siepe M, Stiller B.

Catheter Cardiovasc Interv. 2016 Jan 2. doi: 10.1002/ccd.26393. [Epub ahead of print]

PMID: 26724789

Similar articles

Select item 26774238

 

  1. Serial assessment of arterial structure and function in patients with coarctation of the aorta undergoing stenting.

Jesus CA, Assef JE, Pedra SR, Ferreira WP, Davoglio TA, Petisco AC, Saleh MH, Le Bihan DC, Barretto RB, Pedra CA.

Int J Cardiovasc Imaging. 2016 Jan 2. [Epub ahead of print]

PMID: 26723574

Similar articles

Select item 26349564

 

  1. Haemodynamic impact of stent implantation for lateral tunnel Fontan stenosis: a patient-specific computational assessment.

Tang E, McElhinney DB, Restrepo M, Valente AM, Yoganathan AP.

Cardiol Young. 2016 Jan;26(1):116-26. doi: 10.1017/S1047951114002765. Epub 2015 Feb 25.

PMID: 25712430

Similar articles

Select item 25613755

 

  1. Recent advances in transcatheter pulmonary valve delivery.

Ringewald JM.

Curr Opin Cardiol. 2016 Jan;31(1):88-94. doi: 10.1097/HCO.0000000000000241.

PMID: 26599062

Similar articles

Select item 26569087

 

  1. Renal sympathetic denervation in uncontrolled arterial hypertension after successful repair for aortic coarctation.

Lurz P, Okon T, Riede T, Wagner R, Schuler G, Daehnert I, Desch S.

Int J Cardiol. 2016 Jan 1;202:322-7. doi: 10.1016/j.ijcard.2015.09.034. Epub 2015 Sep 21.

PMID: 26422021

Similar articles

Select item 26407046

 

  1. Usefulness of Percutaneous Transluminal Coronary Balloon Angioplasty for the Left Coronary Artery Stenosis 10 Years More Than After Arterial Switch Operation.

Tsujii N, Tsuda E, Asaumi Y, Yamada O.

Pediatr Cardiol. 2016 Jan 29. [Epub ahead of print]

PMID: 26825593

Similar articles

Select item 26821845

 

  1. Haemodynamic characterisation and heart catheterisation complications in children with pulmonary hypertension: Insights from the Global TOPP Registry (tracking outcomes and practice in paediatric pulmonary hypertension).

Beghetti M, Schulze-Neick I, Berger RM, Ivy DD, Bonnet D, Weintraub RG, Saji T, Yung D, Mallory GB, Geiger R, Berger JT, Barst RJ, Humpl T; TOPP investigators.

Int J Cardiol. 2016 Jan 15;203:325-30. doi: 10.1016/j.ijcard.2015.10.087. Epub 2015 Oct 23.

PMID: 26583838

Similar articles

Select item 26547729

 

  1. Reversing left bronchus obstruction by compression of a pulmonary artery stent.

Brown SC, Proesmans M, Gewillig M.

Catheter Cardiovasc Interv. 2016 Jan 13. doi: 10.1002/ccd.26396. [Epub ahead of print]

PMID: 26762468

Similar articles

Select item 26757980

 

  1. Transcatheter Versus Surgical Closure of Atrial Septal Defects in Children: A Value Comparison.

Ooi YK, Kelleman M, Ehrlich A, Glanville M, Porter A, Kim D, Kogon B, Oster ME.

JACC Cardiovasc Interv. 2016 Jan 11;9(1):79-86. doi: 10.1016/j.jcin.2015.09.028.

PMID: 26762915

Similar articles

Select item 26754187

 

  1. Modified Technique to Create Diabolo Stent Configuration.

Aldoss O, Divekar A.

Pediatr Cardiol. 2016 Jan 6. [Epub ahead of print]

PMID: 26739005

Similar articles

Select item 26739004

 

  1. Cost comparison of Transcatheter and Operative Pulmonary Valve Replacement (from the Pediatric Health Information Systems Database).

O’Byrne ML, Gillespie MJ, Shinohara RT, Dori Y, Rome JJ, Glatz AC.

Am J Cardiol. 2016 Jan 1;117(1):121-6. doi: 10.1016/j.amjcard.2015.10.011. Epub 2015 Oct 17.

PMID: 26552510

Similar articles

Select item 26032628

 

  1. Unruptured Sinus of Valsalva Aneurysm Obstructing the Left Ventricular Outflow Tract: An Uncommon Presentation in Childhood.

Murli L, Shah P, Sekar P, Surya K.

Ann Thorac Surg. 2016 Jan;101(1):e21-3. doi: 10.1016/j.athoracsur.2015.06.102.

PMID: 26694306

Similar articles

Select item 26694282

 

  1. Multi-modal imaging support in a staging percutaneous pulmonary valve implantation.

Chessa M, Giugno L, Butera G, Carminati M.

Eur Heart J. 2016 Jan 1;37(1):66. doi: 10.1093/eurheartj/ehv208. Epub 2015 Jun 7. No abstract available.

PMID: 26056126

Similar articles

Select item 25694470

 

  1. Interactive virtual stent planning for the treatment of coarctation of the aorta.

Neugebauer M, Glöckler M, Goubergrits L, Kelm M, Kuehne T, Hennemuth A.

Int J Comput Assist Radiol Surg. 2016 Jan;11(1):133-44. doi: 10.1007/s11548-015-1220-3. Epub 2015 May 16.

PMID: 25976833

Similar articles

Select item 26503013

 

  1. Endovascular repair of pseudoaneurysms after open surgery for aortic coarctation.

Kotelis D, Bischoff MS, Rengier F, Ruhparwar A, Gorenflo M, Böckler D.

Interact Cardiovasc Thorac Surg. 2016 Jan;22(1):26-31. doi: 10.1093/icvts/ivv297. Epub 2015 Oct 26.

PMID: 26503013 Free Article

Similar articles

Select item 26487434

 

  1. Minimal invasive lung support via umbilical vein with a double-lumen cannula in a neonatal lamb model: a proof of principle.

Schmidt F, Kuebler J, Ganter M, Jack T, Meschenmoser L, Sasse M, Boehne M, Bertram H, Beerbaum P, Koeditz H.

Pediatr Surg Int. 2016 Jan;32(1):75-82. doi: 10.1007/s00383-015-3815-8. Epub 2015 Oct 28.

PMID: 26507850

Similar articles

Select item 26681782

 

  1. Melody Valve Bartonella henselae Endocarditis in an Afebrile Teen: A Case Report.

Sosa T, Goldstein B, Cnota J, Bryant R, Frenck R, Washam M, Madsen N.

Pediatrics. 2016 Jan;137(1):1-4. doi: 10.1542/peds.2015-1548. Epub 2015 Dec 11.

PMID: 26659816

Similar articles

Select item 26644486

 

  1. New approaches to reduce radiation exposure.

Hill KD, Einstein AJ.

Trends Cardiovasc Med. 2016 Jan;26(1):55-65. doi: 10.1016/j.tcm.2015.04.005. Epub 2015 Apr 15. Review.

PMID: 25962784

Similar articles

Select item 26715003

 

  1. Disseminated Peripheral Mycotic Aneurysms and Septic Embolizations Related to an Infected Stent Deployed for Restenosis of Surgically Repaired Supravalvular Aortic Stenosis.

Koray A, Akalın F, Şaylan Çevik B, İsbir S, Arsan S.

World J Pediatr Congenit Heart Surg. 2016 Jan;7(1):104-7. doi: 10.1177/2150135115578179.

PMID: 26715003

Similar articles

Select item 26715002

 

(No Ratings Yet)
Loading...Loading...